Cold storage rooms
The cold storage room is a room or container mounted inside an enclosure or outside with the role of keeping various products at refrigeration or freezing temperatures.
Created to meet the high standards required by retail, catering and the industrial sector, the refrigeration and freezing rooms convince by the high technique used, by the energy efficiency, by the hygienic properties and by the high comfort of use.
The cold storage rooms sold by Topk Utilaje Alimentare are suitable for agri-food markets, butchers, butchers, slaughterhouses, supermarkets, for hotels, bakeries and large pastry shops and in general for any facility in which food production is done at a medium level, our cold storage rooms maintain high hygiene standards and allow the storage of considerable quantities of products, thus ensuring the continuity of the distribution chain, beyond the daily possibilities of production.
Depending on the storage needs, Topk Utilaje Alimentare can offer you refrigeration rooms with sandwich panels with polyurethane insulation 80mm - 120mm and with temperatures in the ranges: 0 / +8 (refrigeration) 10 / -25 ° C (freezing)
The efficiency of the cold rooms
The cold rooms are composed of:
- The room itself is most often made of sandwich panels with the exterior of different materials depending on the outdoor or indoor placement area.
- The refrigeration system that is purchased separately
The main components of the refrigeration system are:
- Refrigeration unit - is a complex equipment that has in its component: compressor, refrigeration condenser, liquid tank, pressure switch, support for all this.
- Vaporizer (also known as evaporator or blower) - absorbs heat from the cold room.
- Electronic temperature controller (thermostat) and lighting
- Other parts: rolling valve, copper pipe, refrigerant (freon), defrost resistance
Insulation of cold rooms
The role of insulation is to prevent hot air from entering the room. If the insulation is of poor quality or insufficient, the penetration of heat into the room will cause more frequent starts of the refrigeration compressor leading to its early aging, it being in fact the most expensive part of a refrigeration system. Frequent compressor starts also increase power consumption.
Cases and effects:
- Insufficient insulation and / or undersized refrigeration unit (less than the required refrigeration power) leads to:
1.1 Frequent compressor starts
1.2 Operation for a longer period of time than the compressor manufacturer's specifications
This situation causes the early aging of the most expensive part of a refrigeration system, the compressor.
- Refrigeration system (refrigeration unit and evaporator) undersized as refrigeration power causes:
2.1 low chances to reach the desired temperature in the cold room
2.2 The refrigeration unit compressor will operate continuously leading to its early failure
The cold rooms sold by us have panels with polyurethane insulation with a density of 42 kg / m³ with a thermal conductivity rate of λ = 0.020 W / m * K (IPR) / λ = 0.022 W / m * K (PUR) , that is, they have an optimal yield in environments where temperatures reach up to 43 ° C.
In addition, in case of a voltage drop, the very good insulation will protect the room and will keep the products at the desired temperature even if the refrigeration system does not work for a longer period of time.
Location of cold rooms
A cold room can be located outside or inside another room. Generally, containers are used for the exterior (for ease of installation).
Their major disadvantage is that they are directly exposed to the outside temperature and therefore require better insulation and higher cooling powers.
Additional costs arise because the compressor requires crankcase resistance (this resistance heats the oil in the compressor when outside temperatures are low to bring the oil into the optimum liquid operating state).
The operating mode of the compressor differs from one season to another. The refrigeration chamber inside a room has as its first advantage the approximately constant maintenance of the outside temperature and the compressor will operate in the same regime throughout the year, regardless of the season.
The dimensions of the cold room
The necessary refrigerating power is calculated according to the volume of the room because the air must have the same temperature in the whole volume.
Hot air has the property of rising. If the refrigeration requirement is not calculated correctly, there will be temperature differences of a few degrees between the ceiling and the floor.
The products in the room will not have the same temperature and the difference between the levels cannot be controlled.
Wall structure
Each construction material: brick, BCA, concrete slab, double glazing, etc., have their own thermal insulation coefficient. The degree of insulation of these materials is generally low.
In the field of artificial cold, the insulation is made inside the room, in order not to allow the obtained cold to be lost in the structure of the walls. The external insulation of a cold room is not taken into account.
The efficient insulation of a cold room is given by:
- Type of insulation material (mineral wool, sandwich panel, polystyrene, polyurethane, etc.)
- Insulation thickness
- Location of insulation (walls, floor, ceiling)
Opening the room door
Every time the door is opened to enter and exit a refrigerated room, a cold leak automatically occurs.
The warm air from outside the room enters through the hollow of the door heating the air volume. This causes the refrigeration compressor to start to bring the air back to the desired temperature.
In case of medium or heavy traffic and when the doors are left open for a long time to remove or introduce the goods in the cold room, it is recommended to install the pvc curtain strips inside the door.
The PVC curtain has a thermal insulating role, minimizing the penetration of heat into the room but also of insects or dust.
Product storage
It is important to know the type of product stored in the cold room because each product needs a certain time to give off heat and differs depending on the water content, cell density, etc.
The packaged product
The packaging of the product is an insulating barrier to heat loss. Each type of packaging - cardboard, aluminum, etc. - has a certain degree of insulation that requires a longer cooling time.
Product temperature at the entrance to the room
The temperature of the product translates into a load of caloric energy that will have to be released to the air in the cold room and then cooled by the refrigeration system. The refrigerating power of the installation is lower for the cases in which the temperature of the product is close to the storage temperature.
In order to benefit from an efficient cold room purchased at a fair price, it is important:
- The insulation of the room should be done as well as possible (inside)
- The most accurate information regarding the construction, loading and use of the camera
- The capacity of the refrigerating unit chosen accordingly for the degree of occupation of the refrigerating roomand the temperature difference necessary for maintaining the products.
Topk Food Machinery specialists are at your disposal and can help you choose the right cold room for your needs.